Altigen MultiSite Configurator Instrukcja Instalacji Strona 184

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 183
Board Configuration
AltiWare OE System Installation & Administration Manual 155
Board Configuration
For information on how to install Triton T1/PRI boards, refer to the Quick
Installation Guide provided with every board package.
Service Parameters for T1
To subscribe to T1 service, certain parameters are required to establish
service. The information provided below identifies the recommended and
supported parameters for T1 service.
T1 Service Request Information
When ordering T1 service, provide the following service request
information:
Equipment Information
Product Manufacturer - AltiGen Communications, Inc.
Product Name - AltiServ PBX Phone System
CSU/DSU -ADTRANT1ACE(recommended)orotherCSU/DSU
Technical Information for T1 with Voice
Signaling Protocol:
E&M Wink Start (recommended)
E&M Immediate Start
Ground Start
Loop Start (not recommended)
Trunk Type:
•DID
2-Way DID (recommended)
DOD
Framing:
Super Frame (SF)/D4
Extended Super Frame (ESF) (recommended)
Line Coding:
Alternate Mark Inversion (AMI)
B8ZS (recommended)
Przeglądanie stron 183
1 2 ... 179 180 181 182 183 184 185 186 187 188 189 ... 454 455

Komentarze do niniejszej Instrukcji

Brak uwag