To configure SIP-Tie Trunks, follow these steps:
1. Open the MultiVoIP configuration tool.
2. Select Configuration > Voice/Fax and configure these parameters:
• Set Select Channel to Channel 3
• Set DTMF to Out of Band – Fixed Duration
• Set Out Of Band Mode to SIP Info
• Set Coder to Manual
• Set Auto Call/OffHook Alert to Auto Call
• Check Generate Local Dial Tone.
• Set Phone Number to 150 (This means when the gateway sends a call to MaxCS, it will try to
ring extension 150. If extension 150 does not exist, the call will be sent to the MaxCS Auto
Attendant system.)
3. Select Configuration > Interface and configure the following parameters:
• Set Select Channel to Channel 3
• Set Interface Type to FXO